DataSheet Solid State Contactor DRC Series ? 7.6 Amp Motor Controller rated Solid State Contactor ? Load voltage range up to 530VAC ? Fits standard 35mm DIN-RAIL ? LED input status indicator ? AC or DC control ? Zero-crossing (resistive loads) or instantaneous turn-on (inductive loads) output ? C-UL-US Listed, IEC Rated, CE & RoHS Compliant, Horsepower Rated ? Built in Overvoltage Protection ? Ultra-efficient thermal management design (Patented) Start / Stop Reversing Solicon DRC3 Series are Solid State Contactors intended for frequently switching on and off three phase loads up to 5 HP, 480 VAC 7.6 Amps. They are available in both contactor versions DRC3P and reversing contactor versions DRC3R. The Solicon Contactor DRC3P is available in either instantaneous turn-on (for Motor Control) or zero voltage turn-on (for Resistive Loads). It is available in either 2 or 3 controlled leg versions. The 2 legs control version is particularly suitable for motor control circuits where the neutral conductor is not utilized. The Solicon Reversing Contactor DRC3R includes an interlock control that allows only off, forward and reverse operation in a safe mode while providing high space saving; it switches instantaneously upon application of the control voltage unless an instantaneous change of direction is commanded, then it will delay the direction change by 100msec in order to prevent simultaneous forward and reverse operations. All the models of Solicon DRC3 Series combine the benefits and advantages of a solid state contactor with the functionality and simplicity of use of an electromechanical contactor thanks to the proprietary thermal management technology (Patented) and complete electrical insulation (no grounding required); the embedded auxiliary contacts, normally open and/or normally closed are intended to be used at 18-280Vac. Three different control voltages are available in order to cover most the applications. All models include overvoltage protection. PRODUCT SELECTION Control Voltage Without Auxiliary Contact 1 NO+NC Auxiliary Conctat 2 NO Auxiliary Contact 230 VAC DRC3P48A400, DRC3R48A400 DRC3P48A411 120 VAC DRC3P48B400, DRC3R48B400 DRC3P48B411 24 VAC/DC DRC3P48D400, DRC3R48D400 DRC3P48D411 DRC3P48A420, DRC3R48A420 DRC3P48B420, DRC3R48B420 DRC3P48D420, DRC3R48D420 AVAILABLE OPTIONS Required for valid part number For options only and not required for valid part number Do not forget to visit us at: www.crydom.com Copyright ? 2014 Custom Sensors & Technologies. Specifications subject to change without notice. DRC Series Operating Voltage 40: 400 VAC (3R function only) 48: 480 VAC Control Voltage A: 230 VAC B: 120 VAC D: 24 VAC/DC Function 3P: Contactor 3R: Reversing Contactor 48 D 3P Load Current per Phase 4: 7.6 Amp FLA (x2 Controlled Legs & 3R function); 4.8 Amp FLA (x3 Controlled Legs only) 4 Auxiliary Contacts, N.O. - N.C. 00: Not included 11: 1 Solid State Auxiliary Contact, Normally Open; 1 Solid State Auxiliary Contact, Normally Closed (3P function only) 20: 2 Solid State Auxiliary Contacts, Normally Open 00 Switching Mode (3P function only) Blank: Zero Voltage Turn-On R: Instantaneous Turn-On Controlled Legs (3P function only) Blank: 3 Controlled Legs 2: 2 Controlled Legs R 2 GENERAL SPECIFICATIONS(1) Description Parameters Dielectric Strength, Input/Output/Base (50/60Hz) (4) 3750 Vrms Minimum Insulation Resistance (@ 500 V DC) 109 Ohm Maximum Capacitance, Input/Output 20 pF Ambient Operating Temperature Range -30 to 80 °C Ambient Storage Temperature Range -40 to 100 °C Weight (typical) 2 Controlled Legs (6.940 oz [196.7 g]) / 3 Controlled Legs (8.050 oz [228 g]) Housing Material UL94 V-0 Housing Color Black and Light Gray LED Status Indicator (color) (7) Forward (Green) / Reverse (Amber) Short Circuit Current Rating (10) 100KA Control and Auxiliary Contact Terminal Screw Torque Range (in-lbs/Nm) 12 / 1.36 Load Terminal Screw Torque Range (in-lbs/Nm) 15 / 1.7 Input Terminal Wire Capacity 18-12 AWG (IEC 1-4 mm2) (standed /solid) OUTPUT SPECIFICATIONS (1) DRC3Pxxxx-2 DRC3Pxxxx Description Load Current, Resistive UL508/AC51 @ 40°C [Arms] (3) 5 7.6 Load Current, Motor Controller UL508/AC53 @ 480VAC [Arms] (3) 4.8 7.6 Minimum Load Current [Arms] 0.15 0.15 Maximum Surge Current [Apk] 1 Cycle 60Hz 750 750 Maximum Surge Current [Apk] 1 Cycle 50Hz 716 716 Maximum I2 t for Fusing (8.33msec)[A2 sec] 2330 2330 Maximum I2 t for Fusing (10msec)[A2 sec] 2560 2560 Maximum On-State Voltage Drop @ Rated Current [Vrms] 1.15 per channel 1.15 per channel Minimum Power Factor (with Maximum Load) 0.5 0.5 Ratings according to UL 508/IEC60947-4-2 [HP/KW]: 240 VAC 1/.75 2/1.5 Ratings according to UL 508/IEC60947-4-2 [HP/KW]: 400 VAC 2/1.5 3/2.2 INPUT SPECIFICATIONS (1) Description Option B Control Voltage Range 90-140 (VAC) Minimum Turn-On Voltage (5) 90 (VAC) Must Turn-Off Voltage 20 (VAC) Minimum Input Current (for on-state) [mA] 5 Maximum Input Current [mA] 8 Nominal Input Impedance 16.4 K Maximum Delay to Turn-On [msec] (8) 20 Option A 208-265 (VAC) 208 (VAC) 60 (VAC) 5.5 7.7 36 K 20 Ratings according to UL 508/IEC60947-4-2 [HP/KW]: 480 VAC 3/2.2 5/3.7 Option D 18-30 (VAC / VDC) 18 (VAC / VDC) 7 (VAC / VDC) 10 22 1.3 K 20 SOLID STATE AUXILIARY CONTACTS(1) Description Operating Voltage Range (47-63Hz) [Vrms] (11) Transient Overvoltage [Vpk] Maximum Load Current [Arms] Minimum Load Current [mA] Maximum Surge Current [Apk] 1 Cycle 60Hz Maximum Surge Current [Apk] 1 Cycle 50Hz Maximum I2 t for Fusing (8.33msec)[A2 sec] Normally Open Suf?x 2x,1x 18-280 600 1 5 40 38 6.7 Normally Closed Suf?x x1 18-280 600 1 5 40 38 6.7 Maximum I2 t for Fusing (10msec)[A2 sec] Maximum Off-State Leakage Current @ Rated Voltage [mArms] Minimum Off-State dv/dt @ Maximum Rated Voltage [V/?sec] Maximum Delay to Turn-On [msec] (8) Maximum Turn-Off Time [msec] (9) 7.2 0.1 500 20 30 7.2 5 mA 500 20 30 DataSheet Solid State Contactor Do not forget to visit us at: www.crydom.com Copyright ? 2014 Custom Sernsors & Technologies. Specifications subject to change without notice. Operating Voltage (47-63Hz) [Vrms] 48-530 48-530 Transient Overvoltage [Vpk] (2) 1200 1200 Maximum Off-State Leakage Current @ Rated Voltage [mArms] 3.0 3.0 Maximum Off-State dv/dt @ Maximum Rated Voltage [V/?sec] 500 500 DRC3R48xxx DRC3R40xxx 7.6 7.6 7.6 7.6 0.15 0.15 750 625 716 597 2330 1621 2560 1779 1.15 per channel 1.5 per channel 0.5 0.5 2/1.5 2/1.5 3/2.2 3/2.2 - 5/3.7 48-415 48-510 1200 1600 3.5 3.5 500 500 Output Terminal Wire Capacity 18-10 AWG (IEC 1-6 mm2 (standed /solid) Humidity 85% non-condensing Maximum Turn-Off Time [msec] (9) 30 30 30 Protection Degree IP20 Pollution Degree 2 MECHANICAL SPECIFICATIONS(1) Tolerances: ±0.02 in / 0.5 mm All dimensions are in: inches [millimeters] (6) 6 5 4 3 2 1 10 0 20 30 40 50 60 70 80 0 Ambient Temperature (?C) Load Current (Amps) THERMAL DERATE INFORMATION DRC3Pxx (3 legs controlled) Single unit Multiple units (6) Ambient Temperature (?C) Load Current (Amps) DRC3Pxx-2 (2 legs controlled) Single unit Multiple units 8 7 6 5 4 3 2 1 0 20 10 30 40 50 60 70 80 0 DataSheet Solid State Contactor Do not forget to visit us at: www.crydom.com Copyright ? 2014 Custom Sensors & Technologies. Specifications subject to change without notice. (6) Ambient Temperature (?C) Load Current (Amps) DRC3R Single unit Multiple units 8 7 6 5 4 3 2 1 0 20 10 30 40 50 60 70 80 0 Top/Bottom view (Fig. 1) Fig. 1 GENERAL NOTES (1) All parameters at 25°C unless otherwise speci?ed. (2) For DRC3P relay will self trigger between 900-1200V, Not suitable for capacitive loads (3) Mounted in the Vertical position. (4) For input to auxiliary output the dielectric strength is 2.5KV. (5) For low temperature operation consider nominal control voltage. (6) Minimum spacing to obtain max. current is 22mm between adjacent units. (7) Reverse Amber Indicator is for DRC3R models only. (8) For DRC3R the turn-on time is 100ms ± 30ms. For DRC3P Instantaneous Turn-on, Option D, turn-on time is 1 msec. (9) For DRC3R the turn-off time is 20ms. (10) When protected with J Class fuses rated 600 VAC, 20 A or equivalent (11) Operating voltage range 18-30 VDC is also valid when used to latch the DRC contactor control input. (12) Derate information is valid when DCR contactors are used with or without accessories, installed on top and/or bottom. (13) For DRC3P models external loads can be connected in parallel to the control input. TERMINAL SCREW TYPE INPUT STATUS XXXX IND. CONT. EQ. DRC3 1.23 [31.19] 2.29 [58.26] 2.58 [65.53] 1.68 [42.67] 3.41 [86.71] 1.78 [45.31] 3.78 [96.02] 3.51 [89.16] 2.92 [74.17] 0.23 [5.84] A1 A2 A3 23 13 24 14 (12) SWITCHING FREQUENCY/LOAD CHARACTERISTIC FOR ALL DEVICES IL : Load Operating Current IR : Rated Full Load Current [FLA] ID : Direct-On-Line Inrush Current tL : Load Operating Current Time tD : Direct-On-Line Inrush Current Time tC : Cycle Time tOn : On Time tOff : Off Time DataSheet Solid State Contactor Do not forget to visit us at: www.crydom.com Copyright ? 2014 Custom Sensors & Technologies. Specifications subject to change without notice. Without overload relay (limit given by the contactor itself) With overload relay (limit given by the overload relay itself) tD (sec) 0.1 1 10 100 0.05 5000 2700 350 35 0.1 3200 1950 350 35 0.2 950 320 35 0.4 500 280 35 0.8 290 160 35 1.6 110 30 3.2 75 25 tOn (sec) tD (sec) 0.1 1 10 100 0.05 6000 3550 350 35 0.1 4100 3000 350 35 0.2 1300 350 35 0.4 700 320 35 0.8 400 320 35 1.6 125 35 3.2 90 35 tOn (sec) tD (sec) 0.1 1 10 100 0.05 7450 3200 350 35 0.1 4050 2100 350 35 0.2 1200 350 35 0.4 650 320 35 0.8 350 280 35 1.6 180 35 3.2 90 35 tOn (sec) tD (sec) 0.1 1 10 100 0.05 9000 3550 350 35 0.1 5400 3550 350 35 0.2 1700 350 35 0.4 850 350 35 0.8 560 350 35 1.6 240 35 3.2 180 35 tOn (sec) tD (sec) 0.1 1 10 100 0.05 2200 1650 330 30 0.1 1500 1000 280 28 0.2 550 255 26 0.4 250 150 24 0.8 80 60 20 1.6 40 16 3.2 tOn (sec) tD (sec) 0.1 1 10 100 0.05 2800 1800 320 35 0.1 1700 1300 310 32 0.2 650 290 30 0.4 300 200 26 0.8 200 90 25 1.6 65 25 3.2 tOn (sec) tD (sec) 0.1 1 10 100 0.05 5150 2800 260 35 0.1 2850 1920 250 34 0.2 1100 250 33 0.4 600 200 32 0.8 320 200 30 1.6 120 25 3.2 75 20 tOn (sec) tD (sec) 0.1 1 10 100 0.05 5600 3200 350 35 0.1 3200 2700 350 35 0.2 1400 350 35 0.4 700 350 35 0.8 350 280 35 1.6 170 35 3.2 80 25 tOn (sec) Table 1 ? High inrush current (ID/IR = 4 to 7.2) ? Full load (IL/IR= 1) Table 2 ? High inrush current (ID/IR = 4 to 7.2) ? 60% load (IL/IR= 0.6) Table 3 ? Low inrush current (ID/IR < 4 ) ? Full load (IL/IR= 1) Table 4 ? Low inrush current (ID/IR < 4 ) ? 60% load (IL/IR= 0.6) Table 5 ? High inrush current (ID/IR = 4 to 7.2) ? Full load (IL/IR= 1) Table 6 ? High inrush current (ID/IR = 4 to 7.2) ? 60% load (IL/IR= 0.6) Table 7 ? Low inrush current (ID/IR < 4 ) ? Full load (IL/IR= 1) Table 8 ? Low inrush current (ID/IR < 4 ) ? 60% load (IL/IR= 0.6) ID IR IL tD tL tC tOn tOff MAXIMUM ALLOWABLE NUMBER OF STARTS PER HOUR DEPENDING ON THE STARTING TIME tD AND THE ON PERIOD tOn (as for standard IEC 60947-4-2) FOR ALL DEVICES - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - DataSheet Solid State Contactor Do not forget to visit us at: www.crydom.com Copyright ? 2014 Custom Sensors & Technologies. Specifications subject to change without notice. SHORT CIRCUIT AND OVERLOAD PROTECTION FOR ALL DEVICES IEC standard 60947-4-1 make a distinction between two different types of protection, (called "coordination"), which are designated types "1" and "2". Any short-circuit that occurs is cleared safely by either type of coordination. The only difference between the 2 categories concerns the extent of the SSR damage caused by the short-circuit. Type "1" coordination requires that in the event of a short-circuit, the Solid State Contactor does not endanger personnel or installations, but permanent damage to the SSC is permissible. In this case the SSC may need to be replaced. For this type of co-ordination, the use of fusing or circuit breakers adequate to protect the system and wiring from short circuits, (but not specifically considering SSC protection), can be used. Type "2" coordination requires that under a short-circuit condition, the circuit is interrupted, the SSC does not endanger persons or installations, and in addition the SSR will be able to operate after the fault condition is repaired. Type of coordination 1 Note: All the Schneider Electric Thermal magnetic circuit breakers GV2 family (GV2ME and GV2P) is fully mechanical compatible with the DRC contactor using the GV2AF3 connection block. Protection by overload relays and fuses Nominal Motor Current Overload Relay (Schneider Electric) Class gG fuses (example from Littlefuse) Solid State Contactor 2 controlled legs Solid State Contactor 3 controlled legs Solid State Contactor Reversing 0.40-0.63 A LRD04 CY14X51G16 DRC3Pxxx4xxx2 DRC3Pxxx4xxx DRC3Rxxx4xx 0.63-1 A LRD05 CY14X51G16 DRC3Pxxx4xxx2 DRC3Pxxx4xxx DRC3Rxxx4xx 1-1.6 A LRD06 CY14X51G25 DRC3Pxxx4xxx2 DRC3Pxxx4xxx DRC3Rxxx4xx 1.6-2.5 A LRD07 CY14X51G25 DRC3Pxxx4xxx2 DRC3Pxxx4xxx DRC3Rxxx4xx 2.5-4 A LRD08 CY14X51G25 DRC3Pxxx4xxx2 DRC3Pxxx4xxx DRC3Rxxx4xx 4-6.3 A LRD10 CY14X51G40 DRC3Pxxx4xxx2 DRC3Pxxx4xxx (up to 4.8A) DRC3Rxxx4xx 6.3-10 A LRD14 CY14X51G40 DRC3Pxxx4xxx2 (up to 7.6A) - DRC3Rxxx4xx (up to 7.6A) Type of coordination 2 Protection by overload relays and fuses Nominal Motor Current Overload Relay (Schneider Electric) Semiconductor fuses with less than 1621A2S (example from Littlefuse) Solid State Contactor 2 controlled legs Solid State Contactor 3 controlled legs Solid State Contactor Reversing 0.40-0.63 A LRD04 LA50QS40-4 DRC3Pxxx4xxx2 DRC3Pxxx4xxx DRC3Rxxx4xx 0.63-1 A LRD05 LA50QS40-4 DRC3Pxxx4xxx2 DRC3Pxxx4xxx DRC3Rxxx4xx 1-1.6 A LRD06 LA50QS40-4 DRC3Pxxx4xxx2 DRC3Pxxx4xxx DRC3Rxxx4xx 1.6-2.5 A LRD07 LA50QS40-4 DRC3Pxxx4xxx2 DRC3Pxxx4xxx DRC3Rxxx4xx 2.5-4 A LRD08 LA50QS40-4 DRC3Pxxx4xxx2 DRC3Pxxx4xxx DRC3Rxxx4xx 4-6.3 A LRD10 LA50QS40-4 DRC3Pxxx4xxx2 DRC3Pxxx4xxx (up to 4.8A) DRC3Rxxx4xx 6.3-10 A LRD14 LA50QS40-4 DRC3Pxxx4xxx2 (up to 7.6A) - DRC3Rxxx4xx (up to 7.6A) All the Schneider Electric Overload relay LRD family is fully mechanical compatible with the DRC contactor without the need of any adapter. 0.40-0.63 A GV2ME04 / GV2P04 DRC3Pxxx4xxx2 DRC3Pxxx4xxx DRC3Rxxx4xx 0.63-1 A GV2ME05 / GV2P05 DRC3Pxxx4xxx2 DRC3Pxxx4xxx DRC3Rxxx4xx 1-1.6 A GV2ME06 / GV2P06 DRC3Pxxx4xxx2 DRC3Pxxx4xxx DRC3Rxxx4xx 1.6-2.5 A GV2ME07 / GV2P07 DRC3Pxxx4xxx2 DRC3Pxxx4xxx DRC3Rxxx4xx 2.5-4 A GV2ME08 / GV2P08 DRC3Pxxx4xxx2 DRC3Pxxx4xxx DRC3Rxxx4xx 4-6.3 A GV2ME10 / GV2P10 DRC3Pxxx4xxx2 DRC3Pxxx4xxx (up to 4.8A) DRC3Rxxx4xx 6.3-10 A GV2ME14 / GV2P14 DRC3Pxxx4xxx2 (up to 7.6A) - DRC3Rxxx4xx (up to 7.6A) Nominal Motor Current Thermal Magnetic Circuit Breaker (Schneider Electric) Solid State Contactor 2 controlled legs Solid State Contactor 3 controlled legs Solid State Contactor Reversing Protection by Thermal Magnetic Circuit Breaker (Conforming to the IEC60947-4-2 and UL508) The DRC Series can accept the LAD7C1 module (pre-wiring kit allowing direct connection of the NC contact of relay LRD to the contactor) When the LAD7C1 module is used, the common terminal for the control input is not anymore the "A2" terminal of DRC but it is the "96" terminal of the overload relay. DataSheet Solid State Contactor Do not forget to visit us at: www.crydom.com Copyright ? 2014 Custom Sensors & Technologies. Specifications subject to change without notice. WIRING AND BLOCK DIAGRAM DRC3P CONTACTOR INPUT STATUS A1 A2 L1 L2 L3 T1 T2 T3 XXXX IND. CONT. EQ. DRC3PXXX400XX INPUT STATUS 13 21 A1 14 22 A2 L1 L2 L3 T1 T2 T3 XXXX IND. CONT. EQ. DRC3PXXX411XX INPUT STATUS 13 23 A1 14 24 A2 L1 L2 L3 T1 T2 T3 XXXX IND. CONT. EQ. DRC3PXXX420XX L1 L2 L3 L1 L2 L3 DRC3Pxxx400xx DRC3Pxxx411xx DRC3Pxxx420xx 48-530 VAC, 50 - 60 Hz CONTROL INPUT CONTROL INPUT 1st Auxiliary Contact (18 - 280 VAC) Normally Open 2nd Auxiliary Contact (18 - 280 VAC) Normally Closed CONTROL INPUT 1st Auxiliary Contact (18 - 280 VAC) Normally Open 2nd Auxiliary Contact (18 - 280 VAC) Normally Open Short circuit and overload current protection (see page 5) T1 T2 T3 General Use / AC-51 Application T1 T2 T3 T1 T2 T3 T1 T2 T3 T1 T2 T3 M 3 Motor Controller / AC-53 Application DRC3P (3 controlled legs model) Main Circuit L1 T1 L2 T2 L3 T3 A1 A2 13 14 23 24 DRC3Pxxx420x (2 Normally Open) Auxiliary Contacts DRC3Pxxx400x Without Auxiliary Contacts DRC3P (2 controlled legs model) Main Circuit L1 T1 L2 T2 L3 T3 A1 A2 13 14 21 22 DRC3Pxxx411x (1 Normally Open - 1 Normally Closed) Auxiliary Contacts (13) DataSheet Solid State Contactor Do not forget to visit us at: www.crydom.com Copyright ? 2014 Custom Sensors & Technologies. Specifications subject to change without notice. DRC3R REVERSING CONTACTOR L1 T1 L2 T2 L3 T3 DRC3R A1 A2 13 14 Forward 23 24 L1 T1 L2 T2 L3 T3 A3 A2 Reverse DRC3Rxxx420 models only INPUT STATUS A1 A2 L1 L2 L3 T1 T2 T3 XXXX IND. CONT. EQ. DRC3RXXX400XX INPUT STATUS 13 23 A1 14 24 A2 L1 L2 L3 T1 T2 T3 XXXX IND. CONT. EQ. DRC3RXXX420XX L1 L2 L3 L1 L2 L3 DRC3Rxxx400xx DRC3Rxxx420xx 48-510 VAC, 50 - 60 Hz CONTROL INPUT (Forward) COMMON FOR CONTROL INPUT CONTROL INPUT (Backward) CONTROL INPUT (Backward) 1st Auxiliary Contact (18 - 280 VAC) Normally Open 2nd Auxiliary Contact (18 - 280 VAC) Normally Open Short circuit and overload current protection (see page 5) T1 T2 T3 T1 T2 T3 T1 T2 T3 M 3 Motor Controller / AC-53 Application Overload current protection needs to be considered CONTROL INPUT (Forward) COMMON FOR CONTROL INPUT A3 A3 Reverse Forward Rev. 020614 DataSheet Solid State Contactor Do not forget to visit us at: www.crydom.com Copyright ? 2014 Custom Sensors & Technologies. Specifications subject to change without notice. AGENCY APPROVALS Certi?cation in accordance with: United States Standard for Industrial Control Equipment - UL 508 and Canadian Standard Association for Industrial Control Equipment – C22.2 No. 14. DRC3 series conforms to the harmonized EN standard EN/IEC 60947-4-2 Electromagnetic Compatibility: IEC 61000-4-2 : Electrostatic Discharge – Level 3 IEC 61000-4-4 : Electrically Fast Transients – Level 3 IEC 61000-4-5 : Electrical Surges – Level 3 Vibration Resistance: IEC 60068-2-6 : Amplitude Range 10-55 Hz, Displacement 0.75mm Shock Resistance: IEC 60068-2-27 : Peak Acceleration 15g, Duration11ms. E116949 FWD REV Open Close Open Close Input A2 Input A3 Open Open Close Close Off On Off Off Off Off On Off TIMING DIAGRAM FOR DRC3R 1, 4, 10 3, 9 4 5 STEP DESCRIPTION A2 is activated, FWD Output wait for 100ms FWD direction is activated A2 change to off. FWD Output is desable at the same time A3 is activated REV Output wait for 100ms 2 6 REV direction is On 8 A3 is open, A2 close, begin 100ms delay 7 Interlock fuction is activated. REV is desable due to A2 & A3 are both activated Initial Condition A2 & A3 open Input/Output 1 2 3 4 5 6 7 8 9 10 Input A2 Input A3 FWD Direction 100 msec 100 msec REV Direction 100 msec TIME DIAGRAM interlock DataSheet Solid State Contactor Do not forget to visit us at: www.crydom.com Copyright ? 2014 Custom Sensors & Technologies. Specifications subject to change without notice. ACCESSORIES FOR ALL DEVICES Recommended Accessories Motor Nominal Current Thermal Magnetic Circuit Breaker (Push Button) Thermal Magnetic Circuit Breaker (Selector) 0.40 - 0.63 A 0.63 - 1 A 1 - 1.6 A 1.6 - 2.5 A 2.5 - 4 A 4 - 6.3 A 6.3 - 10 A Fully compatible with Schneider Electric thermal overload relays & thermal magnetic circuit breakers LRD04 LRD05 LRD06 LRD07 LRD08 LRD10 LRD14 GV2ME04 GV2ME05 GV2ME06 GV2ME07 GV2ME08 GV2ME10 GV2ME14 GV2P04 GV2P05 GV2P06 GV2P07 GV2P08 GV2P10 GV2P14 LR97 D015xx LR97 D015xx LR97 D07xx LR97 D07xx LR97 D07xx LR97 D25xx LR97 D25xx Bimetal Overload Relay Electronic Overload Relay ID Marker Strips CNLB, CNLN, CNL2 Packages of 10 plastic strips comprising 10 individual markers which can be placed for easy identifications during the use of multiple units. Blank Strips Part no.: CNLB Numbered 1 to 10 Strips Part no.: CNLN Numbered 11 to 20 Strips Part no.: CNL2 Note: All the Schneider Electric Thermal magnetic circuit breakers GV2 family (GV2ME and GV2P) is fully mechanical compatible with the DRC contactor using the GV2AF3 connection block. All the Schneider Electric Overload relay LRD family is fully mechanical compatible with the DRC contactor without the need of any adapter. The DRC Series can accept the LAD7C1 module (pre-wiring kit allowing direct connection of the NC contact of relay LRD to the contactor) When the LAD7C1 module is used, the common terminal for the control input is not anymore the "A2" terminal of DRC but it is the "96" terminal of the overload relay. DANGER / PELIGRO / DANGER /GEFAHR / PERICOLO / 危险 HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH. ? Disconnect all power before installing or working with this equipment. ? Verify all connections and replace all covers before turning on power. Failure to follow these instructions will result in death or serious injury. RIESGO DE DESCARGA ELECTRICA O EXPLOSION. ? Desconectar todos los suministros de energia a este equipo antes de trabajar con este equipo. ? Verificar todas las conexiones y colocar todas las tapas antes de energizer el equipo. El incumplimiento de estas instrucciones puede provocar la muerte o lesiones serias. RISQUE DE DESCHARGE ELECTRIQUE OU EXPLOSION ? Eteindre toutes les sources d'énergie de cet appareil avant de travailler dessus de cet appareil ? Vérifier tous connections, et remettre tous couverts en olace avant de mettre sous De non-suivi de ces instructions provoquera la mort ou des lésions sérieuses sérieuses. GEFAHR EINES ELEKTRISCHE N SCHLAGES ODER EINER EXPLOSION. ? Stellen Sie jeglichen Strom ab, der dieses Ger?t versorgt, bevor Sie an dem Ger?t Arbeiten durchführen ? Vor dem Drehen auf Energie alle Anschlüsse überprüfen und alle Abdeckungen ersetzen. Unterlassung dieser Anweisungen k?nnen zum Tode oder zu schweren Verletzungen führen. RISCHIO DI SCOSSA ELETTRICA O DELL'ESPLOSI ONE. ? Spenga tutta l'alimentazion e che fornisce questa apparecchiatu ra prima del lavorare a questa apparecchiatu ra ? Verificare tutti i collegamenti e sostituire tutte le coperture prima della rotazione sull'alimentazi one L'omissione di seguire queste istruz ioni provocherà la morte o di lesioni serie 存在电击、 爆炸或电弧 闪烁危险 ? 在操作此设 备之前请先 关闭电源. 若不遵守这些说明, 可能会导致严重的 人身伤害甚至死亡. WARNING / AVERTISSEMENT / WARNUNG /ADVERTENCIA / AVVERTENZA / RISK OF MATERIAL DAMAGE AND HOT ENCLOSURE ? The product's side panels may be hot, allow the product to cool before touching. ? Follow proper mounting instructions including torque values. ? Do not allow liquids or foreign objects to enter this product. Failure to follow these instructions can result in serious injury, or equipment damage. RISQUE DE DOMMAGE MATERIEL ET DE SURCHAUFFE DU BOITIER ? Les panneaux latéraux du produit peuvent être chauds. Laisser le produit refroidir avant de le toucher. ? Respecter les consignes de montage, et notamment les couples de serrage. ? Ne pas laisser pénétrer de liquide ni de corps étrangers à l'intérieur du produit. Le non-respect de cette directive peut entra?ner, des lésions corporelles graves ou des dommages matériels. Die Nichtbeachtung dieser Anweisung kann K?rperverletzung oder Materialsch?den zur Folge haben. GEFAHR VON MATERIALSCH?DEN UND GEH?USEERHITZUNG ? Die Seitenw?nde k?nnen hei? sein. Lassen Sie das Produkt abkühlen, bevor Sie es berühren. ? Beachten Sie die Montageanweisungen, ? Führen Sie keine Flüssigkeiten oder Fremdk?rper in das Produkt ein. Si no se respetan estas precauciones pueden producirse graves lesiones, da?os materiales. RIESGO DE DA?OS MATERIALES Y DE SOBRECALENTAMIENTO DE LA UNIDAD ? Los paneles laterales del producto pueden estar calientes. Esperar que el producto se enfríe antes de tocarlo. ? Respetar las instrucciones de montaje, y en particular los pares de apretado. ? No dejar que penetren líquidos o cuerpos extra?os en el producto. La mancata osservanza di questa precauzione può causare gravi rischi per l'incolumità personale o danni alle apparecchiature. RISCHIO DI DANNI MATERIALI E D'INVOLUCRO CALDO ? I pannelli laterali dell'apparecchio possono scottare; lasciar quindi raffreddare il prodotto prima di toccarlo. ? Seguire le istruzioni di montaggio corrette. ? Non far entrare liquidi o oggetti estranei in questo apparecchio. 如不能正确执行这些操作说明, 极有可能造成严重人体伤害或者设备的损坏. 材料损坏和高温外壳的危险性 ? 产品的一侧面板可能很热,在其冷却前请 不要触碰. ? 遵照正确的安装说明,包括扭矩值. ? 请勿让液体及其他异物进入本产品. DataSheet Solid State Contactor Do not forget to visit us at: www.crydom.com Copyright ? 2014 Custom Sensors & Technologies. Specifications subject to change without notice. ANNEX - ENVIROMENTAL INFORMATION The environmental information disclosed in this annex including the EIP Pollution logo are in compliance with People's Republic of China Electronic Industry Standard SJ/T11364 – 2006, Marking for Control of Pollution Caused by Electronic Information Products. Part Name Toxic or hazardous Substance and Elements Lead Mercury Cadmium Hexavalent Polybrominated Polybrominated (Pb) (Hg) (Cd) Chromium (Cr (VI)) biphenyls (PBB) diphenyl ethers (PBDE) Semiconductor die Solder 附件 - 环保信息 此附件所标示的包括电子信息产品污染图标的环保信息符合中华人民共和国电子行业标准 SJ/T11364 - 2006, 电子信息产品污染控制标识要求. 有毒有害物质或元素 件部名称 铅汞镉六价铬 多溴联苯 多溴二苯醚 (Pb) (Hg) (Cd) (Cr (VI)) (PBB) (PBDE) 半导体芯片 焊接点 50 DataSheet Solid State Contactor Do not forget to visit us at: www.crydom.com Copyright ? 2014 Custom Sensors & Technologies. Specifications subject to change without notice. 快达固态继电器 Crydom 代理商全国 400 热线 4006-022-002 固态继电器价格 北京(Beijing) 010-68008 911 进口固态继电器经销商 www.shuntu.net 广东省深圳 0755-83656701 上海 021-36588205 固态继电器天津 无锡 DIN 安装固态接触器 SSC 进口固态接触器 导轨安装固体接触器 施耐德固态接触器 三相交流固态接触器 固态交流接触器 UL 认证固态继电器 VDE 认证固态继电器资料 CE 认证固态接触器型号 固态接触器价格 三相固态接触器 SCHNEIDER 固态接触器 固态交流接触器型号 固态接触器控制电压 最大负载电流 线电压范围 DRC3R40A400 230 VAC 7.6 Amps 400 VAC DRC3R40A420 230 VAC 7.6 Amps 400 VAC DRC3R40B400 120 VAC 7.6 Amps 400 VAC DRC3R40B420 120 VAC 7.6 Amps 400 VAC DRC3R40D400 24 VAC/DC 7.6 Amps 400 VAC DRC3R40D420 24 VAC/DC 7.6 Amps 400 VAC DRC3R48A400 230 VAC 7.6 Amps 480 VAC DRC3R48A420 230 VAC 7.6 Amps 480 VAC DRC3R48B400 120 VAC 7.6 Amps 480 VAC DRC3R48B420 120 VAC 7.6 Amps 480 VAC DRC3R48D400 24 VAC/DC 7.6 Amps 480 VAC DRC3R48D420 24 VAC/DC 7.6 Amps 480 VAC DRC3P48A400 230 VAC 4.8 Amps 480 VAC DRC3P48A4002 230 VAC 7.6 Amps 480 VAC DRC3P48A400R 230 VAC 4.8 Amps 480 VAC DRC3P48A400R2 230 VAC 7.6 Amps 480 VAC DRC3P48A411 230 VAC 4.8 Amps 480 VAC DRC3P48A4112 230 VAC 7.6 Amps 480 VAC DRC3P48A411R 230 VAC 4.8 Amps 480 VAC DRC3P48A411R2 230 VAC 7.6 Amps 480 VAC DRC3P48A420 230 VAC 4.8 Amps 480 VAC DRC3P48A4202 230 VAC 7.6 Amps 480 VAC DRC3P48A420R 230 VAC 4.8 Amps 480 VAC DRC3P48A420R2 230 VAC 7.6 Amps 480 VAC DRC3P48B400 120 VAC 4.8 Amps 480 VAC DRC3P48B4002 120 VAC 7.6 Amps 480 VAC DRC3P48B400R 120 VAC 4.8 Amps 480 VAC DRC3P48B400R2 120 VAC 7.6 Amps 480 VAC DRC3P48B411 120 VAC 4.8 Amps 480 VAC DRC3P48B4112 120 VAC 7.6 Amps 480 VAC DRC3P48B411R 120 VAC 4.8 Amps 480 VAC DRC3P48B411R2 120 VAC 7.6 Amps 480 VAC DRC3P48B420 120 VAC 4.8 Amps 480 VAC DRC3P48B4202 120 VAC 7.6 Amps 480 VAC DRC3P48B420R 120 VAC 4.8 Amps 480 VAC DRC3P48B420R2 120 VAC 7.6 Amps 480 VAC DRC3P48D400 24 VAC/DC 4.8 Amps 480 VAC 快达固态继电器 Crydom 代理商全国 400 热线 4006-022-002 固态继电器价格 北京(Beijing) 010-68008 911 进口固态继电器经销商 www.shuntu.net 广东省深圳 0755-83656701 上海 021-36588205 固态继电器天津 无锡 DRC3P48D4002 24 VAC/DC 7.6 Amps 480 VAC DRC3P48D400R 24 VAC/DC 4.8 Amps 480 VAC DRC3P48D400R2 24 VAC/DC 7.6 Amps 480 VAC DRC3P48D411 24 VAC/DC 4.8 Amps 480 VAC DRC3P48D4112 24 VAC/DC 7.6 Amps 480 VAC DRC3P48D411R 24 VAC/DC 4.8 Amps 480 VAC DRC3P48D411R2 24 VAC/DC 7.6 Amps 480 VAC DRC3P48D420 24 VAC/DC 4.8 Amps 480 VAC DRC3P48D4202 24 VAC/DC 7.6 Amps 480 VAC DRC3P48D420R 24 VAC/DC 4.8 Amps 480 VAC DRC3P48D420R2 24 VAC/DC 7.6 Amps 480 VAC 快达 Crydom 继电器 快达固态接触器 快达继电器 PDF 说明书